Tripp Lite SmartOnline 3000VA 2U Rack/Tower On-Line Double-Conversion UPS with 100/110/115/120/127V NEMA Outlets |
(Model # SU3000RTXL2U) Note: Picture may not represent the actual product. We are continuously working on improving our website and reserve the right to change specifications, availability, and pricing without prior notice. SmartOnline 3000VA 2U Rack/Tower On-Line Double-Conversion UPS with 100/110/115/120/127V NEMA Outlets is ideal for critical voice, data, medical and industrial network applications.
UPS Features:
- Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation
- Compact rackmount form factor installs using only 2 rack spaces (2U) with a depth of only 26"
- Economy mode for daily or weekly hours of operation to enable precision output during peak operating hours and high efficiency, low BTU emission operation during off-peak times
- Maintains continuous operation through blackouts, voltage fluctuations and surges
- On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 100/110/115/120/127V (user selectable) with
zero transfer time
- Supports operation at 50/60Hz (auto-sensing) with the ability for full-time frequency conversion from 50 to 60Hz or 60 to 50Hz (frequency
conversion de-rates UPS capacity by 20%)
- Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
- Corrects line voltage conditions as low as 70V and as high as 144V to within 2% of selected nominal voltage
- Standard internal battery set offers 15 minutes runtime at half load (1250W) and 6 minutes at full load (2500W)
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot
- HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints
- Built-in emergency power off (EPO) interface with cable
- Front panel LEDs offer current monitoring and battery charge level information
- Field replaceable, hot swappable internal batteries and external battery packs
- Network grade AC surge suppression
- Output Volt Amp Capacity: 3000VA
- Output Watt Capacity: 2500 watts
- Frequency Compatibility: 60 Hz
- Built-in UPS Output Receptacles: Six 5-15/20R outlets, and one L5-30R outlets
- Full Load Runtime: 6 minutes (2500w)
- Half Load Runtime: 15 minutes (1250w)
| |
|